• marketing@akb.co.id
  • 0812-9696-6494

Product Overview

MEGACF-MB Coriolis flowmeter consists of two parallel tubes that are made to oscillate using a magnet. These oscillations are recorded by sensors fitted at the inlet and outlet of each tube. In a no-flow state, the oscillations are synchronized, i.e. in phase with each other, since there is no mass exerting any force on the tubes. On the other hand, any fluid, or gas flowing through the tubes generates Coriolis forces, causing the tubes to twist in proportion to the mass flow rate of the medium.
High accuracy and high stability over a wide range, 0.1%, 0.2%, 0.5%

  • No time drift or temperature drift
  • Size from 3mm to 250mm
  • Wide temperature range -150 deg C to 300 deg C
  • Excellent for high pressure, up to 26MPa
  • Easy to install
  • Available with pulse, 4-20mA, RS485 and HART
  • Measurement of mass flow, density, temperature, volume flow
  • Measurement and display of percent water-cut for oil/water mixtures
  • Higher Sampling and Digital Filtering


Specification

Flow range1.2~1500000kg/hr
Process connectionsFlanged (ANSI, DIN, Tri-Clamp, Thread)
Line size3~250mm
Process temperature-50~125?(integral), -50~200?(remote), -50~350?(high temp), -200~125?(low temp) 
Tube geometryU-Tube with Micro Bend
Accuracy±0.2% of reading(std), 0.5% or 0.1% (opt)
Repeatability±0.075% of reading
Frequency10-2000 Hz
Engineering units (Mass):kg, lb, ton
Display:Color Graphic OLED
Engineering units (Temp.)°C, °F
Engineering units: (Volume)m³, Liter, US Gallon, Imperial Gallon
Zero stability0.1% full-scale
Ambient temperature-20~60 °C
Zero Drift (%FS / °C)0.005
Max working pressure1.6MPa, 2.5MPa, 4.0MPa, 6.4MPa, 10MPa, 16MPa, 25MPa
Measuring tube materialSS316L
Power supply(18~36)VDC or 85~260)VAC 
Housing materialSS304
Outputs4-20 mA, 0-10 kHz pulse, RS485
CommunicationRS485, HART
Density measuring range0.2~2.0 g/cc
Density accuracy0.001 g/cc)
Temperature accuracup to ±1°C
ProtectionIP67
Explosionstandard type is explosion
Installation

If the medium contains solid particles, mount the meter as shown in position “A”, and in all other cases mount the meter as shown in position “B”. Vertical Mounting is recommended, if the medium contains gas bubbles and solid particles.

pic

PRODUCT DETAILS

  • Product Name:
    Micro-bend Coriolis Mass Flowmeter
  • Product Series:
    MB Series
  • Short Description:
    MEGACF-MB Micro-bend Coriolis mass flowmeters are comprised of two U-Shaped tubes in a casing with a considerably smaller radius than conventional U-Shaped Coriolis flowmeters.

GET QUOTES

Recent Product

Recent Product PT. Alfateh Kember Bersama

Do you want to get our quality service for your business?